J Meta - Bouillon - Supplier for horses

Feeders, Drinking troughs and Heater circulator JMETA

J Meta - Bouillon - Drinkers and feeders

Feeders
Ref. : 5530.10 Straight or angular polyester feeders


Drinking troughs
Ref. : 5515.10 Drinking troughs with pressure adjustment, synthetic bowl

Heater circulator JMETA

Ref. : 5510 the Heater circulator kit JMETA fitted on the frame consists of:

1 5 L Heater
1 Central heating circulator
2 Insulation valves
1 Evacuation valve
1 Closing valve for water supply
2 Check valves
1 Thermometer of return water
1 Differential disconnector 30mA
1 Disconnector 16A for the protection and switch off of the heater
1 Disconnector 2A for the protection and switch off of the circulator

Operation

In summer:
The circulator and the heater are stopped.
The drinking troughs are directly supplied, the direction of the circulation is ensured by check valves.

In winter:
The circulator and the heater are operational.
The t° setting of the heater is done by observing the thermometer at the return of the circuit ; increasing or decreasing the effect of the heater.
It is imperative to check the circulator works well, as it can get blocked after a few months of inactivity.
The water pressure must not exceed 5 bars (see your official installer).

J Meta - Bouillon - Drinkers and feeders

Top